| Diamond
Control Board - The unique Diamond board uses state
of the art technology combined with easy of use to provide
many exceptional new features that cannot be found on any
other board.
2 Wire Maser/Slave
- The Diamond board uses a unique Master/Slave system
that requires only two wires.
Motor Brake - If
the on position is selected, the gate will stop instantly
when it reaches the limit switches. This is essential
on uphill/downhill applications and on all Fail Safe operations.
One Pass - This
tailgating feature works with the reverse loop to allow
only one car to pass. After the car passes the gate closes
instantly, if a second car approaches the gate stops,
and resumes closing once the car has left.
Stop-Reverse -
This radio feature allows the transmitter to work as a
three-button station and is useful for partial opening.
The first command opens the gate, the second stops the
gate, and the third command will close the gate.
Timer - The adjustable
timer can be set from 1 to 60 seconds, with a maximum
run time of 60 seconds.
Overload - If the
motor reaches the stall amp for 3 seconds, it will automatically
shut down.
Receiver - The
receiver terminal is mounted on the control box for easy
installation and is pre-wired for a 3-wire or 4-wire receiver.
Stainless Steel Access
Door - Offers full access to the control board through
the locking stainless steel door.
Gate Opening -
Can operate to either the left or right side.
|
ERD - If the gate
hits an obstruction while closing, it will re-open. If
it hits an obstruction while opening, it will stop, reverse
6 inches and stop again. The sensitivity is adjustable
separately for the open and close cycles.
Global Inputs -
The Diamond board's Global Inputs include key switch,
keypad, exit loop, phantom loop, reverse loop, edge sensor,
open, stop, and close.
Outputs - Outputs
include on board 24 VDC for MAG Lock, alarm, and 24 VAC
auxiliary power.
Safety Alarm -
If the gate hits an object twice while closing or opening,
the system will shut down for 5 minutes. On the Diamond
board you have two options for reset mode. Selecting the
off position will require a manual reset of the board
if the previous happens. However, by selecting the on
position, the system will automatically reset itself.
120 VAC Power Outlets
- The operator contains two 120 VAC Power Outlets for
the users convenience.
Power on/off Switch
- The operator has an easily accessible power disconnect
switch that allows for easy installation and service.
No Pinch Arm -
This safety features prohibits the arm from extending
past the operator's body when the arm is in the fully
extended position.
Warranty - Five
Year residential use.
|